temperature controller -KH501 Manual

High accuracy: +-(0.2%FS+1) Programmable single or universal analog input signals: T.C. RTD, mA DC, mV DC. Suitable for measuring and displaying temperature, pressure, humidity, flow level, vibration etc. Dual windows, four digit, 7 segment LED display, easy to set parameter and alarm value. SMT technology, design more concise; adopts advanced modular structure, flexible configuration. Universal 85-240VAC or 24VDC power supply option, with thunderbolt proof and 10second protection from connecting to 380VAC by mistake. Supporting digit filtering, digital offsetting and thermocouple cold junction auto compensation, flexible maintenance and easy operation. Supporting up to 4 alarm outputs, each alarm can be configured up to HA, HHA, LA,LLA for limits alarms. Supporting auxiliary power supply; 5VDC, 12VDC, 24VDC for external sensor and transmitters. Supporting current retransmission output for signal further transmission. Supporting RS485, RS232 communication based on MODBUS-RTU protocol, configurable with SCADA, OPC servers etc for remote place communication.

Products Details

● Input Impedance :5KΩ ● Input Current: 1~20mA, 10mA suggested. if the pulse voltage is higher than 50V, the current-limit resistance should be connected externally during input ● Measuring Range: 0~6500Hz ● Measuring Accuracy:0.2 grades ● Responding time:≤1s(when setting digital filter parameter l:FiL=0) ● Output Specification: Relay alarm outputs: 220VAC/2A, 220VAC/2A SSR voltage driving output: 12VDC0/30mA SCR contactless output: 100-240VAC/0.2A (continually), 2A(when 20mS, the repeated period time is more than 5S) Auxiliary power supply: 5VDC, 12VDC, 24VDC Linear current retransmission output: 4-20mA default or 0-10mA or customized Communication output: RS485, RS232 serial interface ● Alarm type:High limit, higher limit, low limit, lower limit four alarm types; can up to 3 relay alarm output in a meter. ● Power Supply:85-240VAC,-15%,+10% / 50-60Hz;Or 24VDC/AC,-15%,+10% ● Power consumption:≤5W ● Ambient temperature: 0-50℃ ● Ambient humidity: <85%RHXiamen mitcheil automation co., Ltd. is a professional manufacturer of industrial instruments, advanced technology and CE, ROHS, ISO certification can ensure the quality. Our own production plant can ensure price advantage.
Temperature
At present, the company's trade scale is expanding day by day, customers all over the world, with good reputation has been the trust of customers at home and abroad, our enthusiasm hope: you and I hand in hand, create a better future!Packing: Put PC into bubble bag first, and then into carton Accessories: Manual, U disk Air freight: DHL, TNT and other express
Temperature

Size :mm   (W XH)

OUT1

OUT2

OUT3

Auxiliary Output

Input

Power Supply

A: 96X96 R2A,R2B, I1 R2C,  S1,S2 R2A,R2B   U1,U2,U3 N: Pulse input N: 85-240VAC
B: 48X96 R1A,R1B, I1 R1C,  S1,S2 R1A,R1B U1,U2,U3
C. 96X48
Installation Dimension(mm) :  KH100 (1)
size     model

 A

 B

 C

 D

 E

 F

A

96

48

96

80

160

72

B

96

96

48

160

80

72

C

12

12

12

10.5

10.5

12

Order Code

Description

N

None

R1A

relay outputs: NO ,Capacity: 30VDC/0.8A220VAC/0.8A

R1B

relay outputs: NC, Capacity: 30VDC/0.8A220VAC/0.8A

R1C

relay NO+NC outputs, Capacity: 30VDC/0.8A220VAC/0.8A

R2A

big capacity relay outputs: NO ,Capacity: 30VDC/2A220VAC/2A

R2B

big capacity relay outputs: NC, Capacity: 30VDC/2A220VAC/2A

R2C

big capacity relay NO+NC outputs, Capacity: 30VDC/2A220VAC/2A

I1

Photoelectric isolated and programmable linear current transmission output

S1

Photoelectric isolated RS485 communication interface

S2

Photoelectric isolated RS485 communication interface

U1

Isolated 5VDC auxiliary power supply for external transmitter, sensor or other device. Max. 50mA

U2

Isolated 12VDC auxiliary power supply for external transmitter, sensor or other device. Max. 50mA

U3

Isolated 24VDC auxiliary power supply for external transmitter, sensor or other device. Max. 50mA
Eg :The order code: KH501-A-R2A-I1-N-A, Model: KH501, Panel Size: 96x96mm, A relay NO alarm output, a 4-20mA current retransmission output, universal input, 220VAC power supplyWhen T.C .input, T.C. cold-junction temperature compensation will be needed according to its temperature measuring principle (Please refer relative information).There are three kinds of compensation modes: NULL(no compensation, used for measure), doid (Inner auto temperature component),Cu50(external RTD Cu50 compensation).”diod” compensation can measure the terminal temperature on the bear of the meter and compensate for T.C. cold –junction compensation. But because of the error of measuring component, meter itself heating and other heat source near meter, it usually leads to big deviation of the compensation by “diod” compensation, whose error can be up to 2-4℃ at worst. Please adopts “Cu50” compensation if require higher measuring accuracy: Please connect a external box and put Cu50Cu resistance  purchased in your side and the T.C. cold-junction together and keep them far away from kinds of heating sources, If so, the inconsistency of the measuring caused by compensation is less than 0.5℃If change external Cu resistance to accurate resistance, it can also achieve compensation function of constant temperature bath. For example, please connect 55Ω resistance externally with relative temperature 23.4℃ by Cu50 index table; please put T.C. cold –junction .in constant temperature bath in 23.4℃ to get more accurate compensation, which is higher than Cu resistance compensation. The connection of the two ways of cold-junction compensation as followsThe equipment uses RS485 communication connection acquisition card to achieve real-time recording, monitoring and query  Cloud acquisition software, only NEED 4G wireless module communication, no wiring, easy to install! Mobile phone computer remote view data or graph, at the same time with SMS alarm function.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours