| Size :mm (W XH) | Main Control | OUT1 | OUT2 | OUT3 | OUT4 | Comm. | Input | Power Supply |
| Order Code | ||||||||
| A: 96X96 | R2C,W1,G, K1,C1,C3,I2 | R2A,R2B, I1 | R2C, S1,S2 | R2A,R2BU1,U2,U3 | N | N | N: Universal T:Temperature I: 4-20mA 0-10mA U: 0-5VDC 1-5VDC 0-10VDC | A: 220VAC85-240VAC B.: 110VAC 85-240VAC D: 24VDC |
| B: 48X96 | R1C,W1,G, K1,C1,C3,I2 | R1A,R1B, I1 | R1C, S1,S2 | R1A,R1BU1,U2,U3 | N | N | ||
| C. 96X48 | R1C,W1,G, K1,C1,C3,I2 | R1A,R1B, I1 | R1C, S1,S2 | R1A,R1BU1,U2,U3 | N | N | ||
| D. 160X80 | R2C,W1,G, K1,C1,C3,I2 | R2C, I1 | R2C,U1,U2,U3 | R2C | R2C | S1,S2 | ||
| E:80X160 | R2C,W1,G, K1,C1,C3,I2 | R2C, I1 | R2C,U1,U2,U3 | R2C | R2C | S1,S2 | ||
| F: 72X72 | R2C,W1,G, K1,I 2 | R2CU1,U2,U3 | R2C, S1,S2 | N | N | N | ||
| G:48X48 | R1C,G,I1, U1,U2,U3 | R1A,R1BI1,S1, U1,U2,U3 | N | N | N | N | ||
Installation Dimension(mm) :
| size model | A | B | C | D | E | F |
| A | 96 | 48 | 96 | 80 | 160 | 72 |
| B | 96 | 96 | 48 | 160 | 80 | 72 |
| C | 12 | 12 | 12 | 10.5 | 10.5 | 12 |
| Z | 100 | 100 | 100 | 84 | 84 | 100 |
| X | 92+0.5 | 45+0.5 | 92+0.5 | 76+0.5 | 152+0.5 | 68+0.5 |
| Y | 92+0.5 | 92+0.5 | 45+0.5 | 152+0.5 | 76+0.5 | 68+0.5 |
| W | 30 | 30 | 8 | 30 | 8 | 30 |
| H | 8 | 8 | 30 | 8 | 30 | 8 |
| Order Code | Description |
| N | None |
| R1A | relay outputs: NO ,Capacity: 30VDC/0.8A,220VAC/0.8A |
| R1B | relay outputs: NC, Capacity: 30VDC/0.8A,220VAC/0.8A |
| R1C | relay NO+NC outputs, Capacity: 30VDC/0.8A,220VAC/0.8A |
| R2A | big capacity relay outputs: NO ,Capacity: 30VDC/2A,220VAC/2A |
| R2B | big capacity relay outputs: NC, Capacity: 30VDC/2A,220VAC/2A |
| R2C | big capacity relay NO+NC outputs, Capacity: 30VDC/2A,220VAC/2A |
| G | SSR driving voltage output (DC 12V/50MA output) |
| W1 | SCR contactless output module (100-240VAC/0/2A) |
| K1 | Single circle SCR zero-crossing trigger output module(each circle triggering dual direction 5-500A or two reserve single direction SCR in series.) |
| I1 | Photoelectric isolated and programmable linear current transmission output |
| I2 | Photoelectric isolated and programmable linear current control output |
| S1 | Photoelectric isolated RS485 communication interface |
| S2 | Photoelectric isolated RS485 communication interface |
| U1 | Isolated 5VDC auxiliary power supply for external transmitter, sensor or other device. Max. 50mA |
| U2 | Isolated 12VDC auxiliary power supply for external transmitter, sensor or other device. Max. 50mA |
| U3 | Isolated 24VDC auxiliary power supply for external transmitter, sensor or other device. Max. 50mA |
| Size Code | Front Panel Width x Height | Cutout Width x Height | Depth Behind |
| A | 96X96mm | 92+0.5 x92+0.5mm | 100mm |
| B | 48x96mm | 45+0.5 x 92+0.5mm | 100mm |
| C | 96x48mm | 92+0.5x45+0.5mm | 100mm |
| D | 160x80mm | 152+0.5 x76+0.5mm | 84mm |
| E | 80x160mm | 76+0.5 x 152+0.5mm | 84mm |
| F | 72x72mm | 68+0.5 x 68+0.5mm | 100mm |
| G | 48x48mm | 45+0.5 x45+0.5mm | 100mm |




When T.C .input, T.C. cold-junction temperature compensation will be needed according to its temperature measuring principle (Please refer relative information).There are three kinds of compensation modes: NULL(no compensation, used for measure), doid (Inner auto temperature component),Cu50(external RTD Cu50 compensation).”diod” compensation can measure the terminal temperature on the bear of the meter and compensate for T.C. cold –junction compensation. But because of the error of measuring component, meter itself heating and other heat source near meter, it usually leads to big deviation of the compensation by “diod” compensation, whose error can be up to 2-4℃ at worst. Please adopts “Cu50” compensation if require higher measuring accuracy: Please connect a external box and put Cu50Cu resistance purchased in your side and the T.C. cold-junction together and keep them far away from kinds of heating sources, If so, the inconsistency of the measuring caused by compensation is less than 0.5℃。If change external Cu resistance to accurate resistance, it can also achieve compensation function of constant temperature bath. For example, please connect 55Ω resistance externally with relative temperature 23.4℃ by Cu50 index table; please put T.C. cold –junction .in constant temperature bath in 23.4℃ to get more accurate compensation, which is higher than Cu resistance compensation. The connection of the two ways of cold-junction compensation as follows:The equipment uses RS485 communication connection acquisition card to achieve real-time recording, monitoring and query
Cloud acquisition software, only NEED 4G wireless module communication, no wiring, easy to install! Mobile phone computer remote view data or graph, at the same time with SMS alarm function.