MIC200BF Mini Paperless Recorder 4Channels

MIC200BF color paperless recorder (72x72x105mm, up to 4 channels) for multi-function record, completely isolated universal input, such as thermocouple, thermal resistance, current voltage, temperature, liquid level, pressure, voltage, current, flow, vibration frequency input; Adopt modularized structure to output alarm, sensor auxiliary power supply, forwarding, printing, communication and other functions. Measurement data can be displayed in a variety of types, such as bar chart graphic display, real-time trend, historical trend memory, real-time circular chart, historical circular chart memory, alarm state display, etc. Curves and data can also be printed by small printer through RS232 port. It also provides the function of viewing data of year, month, day, hour, minute, and second. The recorder can be configured with OPC server, SCADA system and other professional software, using modbus-RTU communication protocol through RS485 port. Historical data can be directly downloaded through the U disk, plug and play, convenient and flexible. The data analysis software supported by PC can print the data into curves and output them in Excel format for further analysis.

Products Details

Analog Input Specification
Input Signal Thermocouple: 7 types (K,S,B,E,J,N,T) RTD-Resistance bulbs: 3 types (Pt100, CU50,CU100) DC Voltage: (0-5VDC, 1-5VDC) DC Current: (4-20mA, 0-10 mA)
Accuracy +-(0.2%FS+1) digit
Sampling Rate 1s/1 channels,
Modular Output Function 
Relay Alarm up to 2 points, 220VAC,0.8A, NO or NC
Retransmission 4-20mA, 0-10Ma,one point
Auxiliary Power Supply for sensors 5V, 12V,24VDC, 50mA for sensor and transmitters
Recording Specification
Memory Media USB memory , FAT16 format
Memory Flash memory
Memory Capacity 2MB built in for long time record
Record Interval 1 to 3600 seconds, settable flexibly
Record Cycle     1 second to 15years by interval time 36hours  per 1s record  interval 90 days per 1 min. record interval…
Recording Method Start recording when power on.      Stop recording when power off.
Data Save Cycle Oldest data replaced by newest data accordingly when memory is full
Data Format Binary format or cannot read or write
Alarm Function
Alarm Indication Alarm States is displayed in digital, When alarm occurs, state flashing
Alarm output Up to 2 points, 0.8A contact
Alarm Setting Individual or common output
Communication Function
Communication Photoelectrical isolated RS485 ,RS232 communication port
Protocol Modbus RTU, can communicate with  modern PLC and HMI directly
Cable RS485 shielded twisted pair cable
Others
Power Supply 85-240VAC, 50/60Hz;  24VDC
Power Consumption Maximum 5VA(5W)
Size 72x72x105mm
Operation Temperature Working Temperature:0-50C Relative humidity; 10%-85%( now dew)
Temperature

Trend Screen

The equipment uses RS485 communication connection acquisition card to achieve real-time recording, monitoring and query
Temperature
Cloud acquisition software, only NEED 4G wireless module communication, no wiring, easy to install! Mobile phone computer remote view data or graph, at the same time with SMS alarm function.
Temperature
Xiamen mitcheil automation co., Ltd. is a professional manufacturer of industrial instruments, advanced technology and CE, ROHS, ISO certification can ensure the quality. Our own production plant can ensure price advantage.
Temperature
At present, the company's trade scale is expanding day by day, customers all over the world, with good reputation has been the trust of customers at home and abroad, our enthusiasm hope: you and I hand in hand, create a better future!Packing: Put PC into bubble bag first, and then into carton Accessories: Manual, U disk Air freight: DHL, TNT and other expressMIC200BF Mini Selection of Paperless Recorder For example : MIC-204BF-R2A-S1-U-N Meaning: Channel -------Four Channels OUT1-------Relay alarm output: NO ,30VDC/3A, 220VAC/3A OUT2-------RS485 communication port , Modbus-RTU protocol USB--------USB flash drive to download data to PC, free PC data analysis software offered Power supply-------85-240VAC Communication

Function

Code and Description

Basic Code

MIC200F 

MIC200BF MINIF Paperless Recorder

Channel

01

One Channel

02

Two Channels

……………

04

Four Channels

OUT1

N

None

R2A

Relay alarm output: NO ,30VDC/3A, 220VAC/3A

R2B

Relay alarm output :NC , 30VDC/0.8A, 220VAC/0.8A
U1 Isolated auxiliary 5VDC power supply for transmitter, sensor and other device, max.100mA

U2

Isolated auxiliary 12VDC power supply for transmitter, sensor and other device, max.100mA

U3

Isolated auxiliary 24VDC power supply for transmitter, sensor and other device, max.100mA
OUT2

N

None

R2C

Relay alarm output: NO+NC ,30VDC/3A, 220VAC/3A

S1

RS485 communication port , Modbus-RTU protocol

S2

RS232 communication port, Modbus-RTU protocol

P

RS232 Printing port for mini printer
USB U USB flash drive for download data, free PC data analysis software offered.

Power supply

N

85-240VAC

D

24VDC
Temperature

Multichannel Screen

Temperature

Display screen on PC

Temperature

Bar graph Screen

Temperature

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours