Accuracy | ±(0.2%FS+1)digit |
Power supply | 85-240VAC |
Display | 3.2inch, 128x64 dot-matrix LCD |
Input Signal | T.C: K, S, E, J, T, B RTD: PT100, CU50, CU100 Linear voltage: 0-5V, 1-5V Linear current: 0-10mA, 4-20mA Others: R, WRe526, mv, etc |
Output Module | Relay alarm output (Max. 8 output) RS485, RS232 Communication port 5VDC, 12VDC, 24VDC aux. power supply RS232 Printing port USB Port |
Record time | Flexible setting interval time: 1s, 2s, 3s, 4s.3600s Record time: 22.5 x record interval time Total channel numbers |
Power-off Protection Time | The setting parameters and history data can be kept by FLASH MEMORY, memorized forever if power off. Hardware clock built in for still accuracy running. |
Size | 160X80X105mm |
Environmental temperature | 0-50℃ |
Environmental humidity | 0-85%RH |
Single channel screen
The equipment uses RS485 communication connection acquisition card to achieve real-time recording, monitoring and query Cloud acquisition software, only NEED 4G wireless module communication, no wiring, easy to install! Mobile phone computer remote view data or graph, at the same time with SMS alarm function. Xiamen mitcheil automation co., Ltd. is a professional manufacturer of industrial instruments, advanced technology and CE, ROHS, ISO certification can ensure the quality. Our own production plant can ensure price advantage. At present, the company's trade scale is expanding day by day, customers all over the world, with good reputation has been the trust of customers at home and abroad, our enthusiasm hope: you and I hand in hand, create a better future!Packing: Put PC into bubble bag first, and then into carton Accessories: Manual, U disk Air freight: DHL, TNT and other expressMIC200B-D Selection of Paperless Recorder For Example : MIC-216B-D-1-R1A-U1-S1-U-N Meaning: Channel -------Sixteen Channels Relay Output-------1 relay output Relay Type-------relay, NO Aux. power supply--------5VDC output Communication-------RS485 port Power Supply-------220, 85-240VAC Communication Function | Code and Description | ||||||||
Basic Code | MIC2 | MIC200B-D Data Logger | |||||||
Channel | 01 | One Channel | |||||||
02 | Two Channels | ||||||||
… | …………… | ||||||||
16 | Sixteen Channels | ||||||||
Relay Output | N | None | |||||||
1 | 1 relay output | ||||||||
2 | 2 relay output | ||||||||
........ | .............. | ||||||||
8 | 8 relay output | ||||||||
Relay Type | N | None | |||||||
R1A | relay, NO | ||||||||
R1B | relay, NC | ||||||||
Aux. power supply | N | None | |||||||
U1 | 5VDC output | ||||||||
U2 | 12VDC output | ||||||||
U3 | 24VDC output | ||||||||
Communication | N | None | |||||||
S1 | RS485 port | ||||||||
S2 | RS232 port | ||||||||
P | RS232 Print port | ||||||||
USB | U | USB port | |||||||
Power Supply | N | 220, 85-240VAC | |||||||
A | 110, 85-240VAC |
Multichannel Screen
Display screen on PC
Bar graph Screen